What is the working principle of a Plate Heat Exchanger? Heat Transfer Explained

What is the working principle of a Plate Heat Exchanger? Heat Transfer Explained

We have Plate Heat Exchanger used to transfer temperature or energy of hot and cold liquids without mixing these two media. The main idea of Plate Heat Exchanger is very straightforward but its performance is based on a combination of factors related to temperature differences, flow channels, interaction of hot and cold fluids and metal surfaces.

Familiarization with Plate Heat Exchanger working principle in industrial applications helps process engineers, buyers, technicians or other operators to get a better understanding of potential heat recovery, heating or cooling effectiveness of their industrial equipment.

What Is a Plate Heat Exchanger?

To put it simple, Plate Heat Exchanger is a kind of device that heats or cools liquids via metal plates. It consists of a number of thin metal plates separated from the liquids they are meant to cool/downheat by sealing arrangements – either gaskets or other sealing means. So the hot and cold fluids won’t be mixed yet heat can be transferred through the plates.

Hot and cold fluids enter Plate Heat Exchanger on either sides. Through the plate the hot one loses heat, while the cold one gains it.

In addition to dividing two fluid streams, the corrugated surface structure of the plates performs several functions at once. It generates turbulent mixing in the channels, maintains flow and supports the plate material. The surface is also the only place of heat exchange as fluid contacts the plate material.

What is most relevant to buyers regarding heat transfer in a Plate HeatExchanger from the counter-current flow perspective is that the direction of flow highly impacts the device’s thermal efficiency.

How Do the Hot and Cold Fluids Flow?

We have two separate flows going inside a Plate Heat Exchanger. The hotter fluid runs on the one channel side, while on the adjacent one the colder fluid.

Metal plates divide the two flow streams physically. At the same time, they allow heat from the hotter side of the plate to reach the cold side of the other stream. Heat exchange occurs without physical contact between fluids.

Counter-flow design is typical for the Plate Heat Exchanger working principle in industrial applications.

Why is it important? In a counter-current heat exchanger the temperature drive is maintained along the flow path over a larger distance compared with parallel flows. The hottest part of one medium becomes the coolest of the other medium and vice versa, so that heat transfer happens at every point and over a long path before the two ends reach equilibrium.

By using such Plate Heat Exchanger heat transfer process explained through counter-current flow, the engineers are able to have the desired output temperatures in heat recovery with much smaller transfer area.

Why Are the Plates Corrugated?

Metal plates installed in a Plate Heat Exchanger are the main elements that do not just divide fluids, but also provide for proper and safe passage of the working media. The pattern of their deformation determines the flow path. The corrugation makes the fluid travel in turbulence.

Heat transfer is enhanced partly due to Plate Heat Exchanger working principle in industrial applications of turbulence. Fluid at high velocity, and in contact with the plates’ walls constantly is one of the characteristics of turbulent flow.

In addition, the corrugated patterns make the adjacent plates resist compression by mechanical support from them. Hence, the stack is able to be pressed while keeping the flow pathways defined and the pressure within it handled.

Conducting the Plate Heat Exchanger heat transfer process explained through counter-current flow involves more than the placing of one fluid next to another.

How to Perform the Counter-Current Heat Trans fer?

Hot water comes in through one side of a Plate Heat Exchanger while cold water flows in from the other side.

The hot side gets its temperature decreased through the hot channels whereas the cold side gets heated while flowing against.

Harnessing the opposite flow is one of Plate Heat Exchanger working principle in industrial applications‘ features to achieve the driving force over a larger part of the system’s heat transfer surface.

The Plate Heat Exchanger heat transfer process explained through counter-current flow is composed of three main points:

1. Thermal energy is released as the hot fluid enters.

2. Heat is conducted via the sheet metal plates.

3. Thermal energy is absorbed into the cold fluid.

Throughout, the two fluid streams remain completely apart.

In this kind of system a Plate Heat Exchanger is a viable choice for heating, cooling, heat recovery, chemical reactions, oil refining, power plant, etc. applications.

SUNWEN’s plate heat exchangers are available to suit many kinds of industrial needs from oil and gas to chemical sectors, power generation, steel making, shipbuilding, air conditioning etc.

What are the Influential Factors affecting Heat Transfer?

In no case a Plate Heat Exchanger will perform to full capacity if all the input conditions do not meet the optimum ones at the same time. The factors, therefore, that an engineer must pay attention to include not only inlet and outlet temperatures but also fluid properties.

Heat transfer in the Plate Heat Exchanger working principle in industrial applications may be influenced, among other factors, by:

· Inlet and outlet temperatures

· Volumetric and flow rates

· Fluid viscosity and density

· Thermal conductivity

· Operating pressure

· Materials resistance

· Fouling or deposition

· Desired heat-transfer duty or output

· Pressure drop in the exchanger channels

Besides material resistance properties, a proper operating temperature difference should be maintained between the two fluids at all times which, of course, depends on the Plate Heat Exchanger heat transfer process explained through counter-current flow in the equipment.

Where the heat duty to be carried out is higher, engineers may be forced to increase heat-transfer area, modify plate pattern, raise flow rate, or rearrange channels depending on the case.

Material choice is also an integral aspect of the system operation, different combinations of metals such as stainless steel and others might suit the fluids and running conditions depending on factors like corrosion, temperature, and pressure levels.

Why So Compact?

The Plate Heat Exchanger compactness is considered one of its strongest points.

Combining features of thin plates separated into small channels, the Plate Heat Exchanger working principle in industrial applications has a huge heat-exchange area but takes only a little space.

Using Plate Heat Exchanger heat transfer process explained through counter-current flow is advantageous when the engineer is restricted by space constraints only and a large amount of heating/cooling is necessary.

Plate design, on the one hand at least, allows for relatively more compact solutions than those of traditional shell-and-tube type especially for some types of heating and cooling duties.

Despite that, the type of heat exchanger chosen is largely a matter of pressure and temperature levels, fluid characteristics and service/ maintenance requirements of the industrial plant.

In addition to that, SUNWEN is one of the companies which can deliver a comprehensive turnkey solution with design, manufacturing, testing, shipping, installation and service works from plate heat exchanger engineering for the most diverse industries on the globe.

Summary

The Plate Heat Exchanger is basically designed so that two fluids go through separate channels formed by the metal plates (mostly corrugated) – hot one through one set of channels and cold the other.

There, heat goes through the plates leaving the fluids untouched.

Plate geometry, temperature difference, flow arrangement, velocity of the fluid, material properties, and other features are all parts of the Plate Heat Exchanger working principle in industrial applications and contribute to the thermal load.

The Plate Heat Exchanger heat transfer process explained through counter-current flow is what explains that opposing the fluid movement can keep the temperature difference effective across the whole of the heat transfer surface.

Possibly the most important thing when it comes to selecting the Plate Heat Exchanger is to consider the process requirements rather than looking at the equipment size. Heat recovery, or the thermal transfer is determined by factors like flow rates, pressure, properties of fluids, nature of the fluids, materials and so forth.

The PlateHeatExchangers that SUNWEN supply are industrial grade and built to the requirements of challenging environments. In particular, a combination of engineering capabilities and manufacturing resources is a unique element that distinguishes their ‍‌products.